<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-28 13-25-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 62 kHz 14908 9,7867
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,8 dBr 4,64 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 62 kHz MIN: 10 kHz % above 76 kHz: 9,7867 Acquired: 2025/03/28 13.24.41 Total samples: 14908 Equivalent time: 0:12:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,5 dBr MIN: 2,8 dBr AVE: 4,64 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2025/03/28 13.24.41) 13.10 13.12 13.14 13.16 13.18 13.20 13.22 13.24 0 2 4 6 Pm [dBr]